Abstract | Purpose: Intensity modulated radiation therapy (IMRT) compensation based on 3D high-dose-rate (HDR) intracavitary brachytherapy (ICBT) boost technique (ICBT + IMRT) has been used in our hospital for advanced cervix carcinoma patients. The purpose of this study was to compare the dosimetric results of the four different boost techniques (the conventional 2D HDR intracavitary brachytherapy [CICBT], 3D optimized HDR intracavitary brachytherapy [OICBT], and IMRT-alone with the applicator in situ). Material and methods: For 30 patients with locally advanced cervical carcinoma, after the completion of external beam radiotherapy (EBRT) for whole pelvic irradiation 45 Gy/25 fractions, five fractions of ICBT + IMRT boost with 6 Gy/fractions for high risk clinical target volume (HRCTV), and 5 Gy/fractions for intermediate risk clinical target volume (IRCTV) were applied. Computed tomography (CT) and magnetic resonance imaging (MRI) scans were acquired using an in situ CT/MRI-compatible applicator. The gross tumor volume (GTV), the high/intermediate-risk clinical target volume (HRCTV/IRCTV), bladder, rectum, and sigmoid were contoured by CT scans. Results: For ICBT + IMRT plan, values of D90, D100 of HRCTV, D90, D100, and V100 of IRCTV significantly increased (p < 0.05) in comparison to OIC |
Keyword | brachytherapy cervical cancer cervix carcinoma dosimetry IMRT |
URL | View the original |
Language | 英語English |
The Source to Article | PB_Publication |
PUB ID | 19625 |
Document Type | Journal article |
Collection | DEPARTMENT OF PHARMACEUTICAL SCIENCES |
Corresponding Author | Tam, K. Y. |
Recommended Citation GB/T 7714 | Yin, G.,Wang, P.,Lang, J.,et al. Dosimetric study for cervix carcinoma treatmentusing intensity modulated radiation therapy(IMRT) compensation based on 3D intracavitarybrachytherapy technique[J]. Journal of Contemporary Brachytherapy, 2016, 221-232. |
APA | Yin, G.., Wang, P.., Lang, J.., Tian, Y.., Luo, Y.., Fan, Z.., & Tam, K. Y. (2016). Dosimetric study for cervix carcinoma treatmentusing intensity modulated radiation therapy(IMRT) compensation based on 3D intracavitarybrachytherapy technique. Journal of Contemporary Brachytherapy, 221-232. |
MLA | Yin, G.,et al."Dosimetric study for cervix carcinoma treatmentusing intensity modulated radiation therapy(IMRT) compensation based on 3D intracavitarybrachytherapy technique".Journal of Contemporary Brachytherapy (2016):221-232. |
Files in This Item: | There are no files associated with this item. |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment