AbstractThis study presents a minimum inverter capacity design for three-phase four-wire centre-split inductor-capacitor (LC) coupling hybrid active power filters (LC-HAPFs). Based on its equivalent circuit models in d–q–0 coordinate, the coupling part filtering characteristics of the LC-HAPF without or with neutral inductor can be more clearly illustrated and easily understood, compared with the past analysis based on the generic filter structure. According to the current quality data, the minimum dc-link voltage expressions for the LC-HAPF without and with neutral inductor are deduced and compared. Conventionally, the coupling LC is usually tuned at a higher fifth- or seventh-order harmonic frequency to reduce its cost and size compared with third-order case. When triplen harmonic currents exist significantly, the LC-HAPF with a small tuned neutral inductor can further reduce its minimum dc-link voltage requirement. Thus, the initial cost, switching loss and switching noise of the LC-HAPF can be lowered. Representative simulation and experimental results of the three-phase four-wire LC-HAPF with neutral inductor are presented to verify the filtering characteristics analysis and minimum dc-link voltage expressions, to show the effectiveness of reducing its inverter capacity, switching loss and switching noise in current quality compensation compared with the conventional LC-HAPF.
KeywordCurrent harmonics hybrid active power filters (HAPFs) minimum inverter capacity neutral inductor reactive power control
Language英語English
The Source to ArticlePB_Publication
PUB ID11873
Document TypeJournal article
CollectionUniversity of Macau
Corresponding AuthorLam, C. S.
Recommended Citation
GB/T 7714
Lam, C. S.,Cui, X. X.,Choi, W. H.,et al. Minimum inverter capacity design for three-phase four-wire LC-hybrid active power filters[J]. IET Power Electronics, 2012, 956-968.
APA Lam, C. S.., Cui, X. X.., Choi, W. H.., Wong, M. C.., & Han, Y. D. (2012). Minimum inverter capacity design for three-phase four-wire LC-hybrid active power filters. IET Power Electronics, 956-968.
MLA Lam, C. S.,et al."Minimum inverter capacity design for three-phase four-wire LC-hybrid active power filters".IET Power Electronics (2012):956-968.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Lam, C. S.]'s Articles
[Cui, X. X.]'s Articles
[Choi, W. H.]'s Articles
Baidu academic
Similar articles in Baidu academic
[Lam, C. S.]'s Articles
[Cui, X. X.]'s Articles
[Choi, W. H.]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Lam, C. S.]'s Articles
[Cui, X. X.]'s Articles
[Choi, W. H.]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.