An ultra low power 9-bit 1-MS/s pipelined SAR ADC for bio-medical applications
Yin G.1,2; Chio U.-F.2; Wei H.-G.2; Sin S.-W.2; U S.-P.2; Martins R.P.2; Wang Z.2,3
2010-12-01
Conference Name2010 17th IEEE International Conference on Electronics, Circuits and Systems
Source Publication2010 IEEE International Conference on Electronics, Circuits, and Systems, ICECS 2010 - Proceedings
Pages878-881
Conference Date12-15 Dec. 2010
Conference PlaceAthens, Greece
Abstract

This paper presents a pipelined successive approximation register analog-to-digital converter (SAR ADC) for bio-medical applications based on 65 nm CMOS technology. Without using op-amp, the proposed 9-bit pipelined SAR ADC can reduce the capacitance from 512C to 64C. The pipelined architecture can enhance the operation efficiency of the ADC and also save the digital power consumption in the SAR. The simulation results show that the total power of the ADC is 10.26 μW only, and the figure of merit (FOM) of the ADC is 28.3 fJ/conversion-step. ©2010 IEEE.

KeywordBio-medical Applications Pipelined Sar Adc Ultra-low Power
DOI10.1109/ICECS.2010.5724652
URLView the original
Language英語English
Scopus ID2-s2.0-79953082608
Fulltext Access
Citation statistics
Document TypeConference paper
CollectionINSTITUTE OF MICROELECTRONICS
Faculty of Science and Technology
DEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING
Affiliation1.Institute of Microelectronic, Tsinghua University, Beijing, China
2.Analog and Mixed Signal VLSI Laboratory, FST, University of Macau, Macau, China
3.On leave from Instituto Superior Tecnico/TU of Lisbon, Portugal
First Author AffilicationFaculty of Science and Technology
Recommended Citation
GB/T 7714
Yin G.,Chio U.-F.,Wei H.-G.,et al. An ultra low power 9-bit 1-MS/s pipelined SAR ADC for bio-medical applications[C], 2010, 878-881.
APA Yin G.., Chio U.-F.., Wei H.-G.., Sin S.-W.., U S.-P.., Martins R.P.., & Wang Z. (2010). An ultra low power 9-bit 1-MS/s pipelined SAR ADC for bio-medical applications. 2010 IEEE International Conference on Electronics, Circuits, and Systems, ICECS 2010 - Proceedings, 878-881.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Yin G.]'s Articles
[Chio U.-F.]'s Articles
[Wei H.-G.]'s Articles
Baidu academic
Similar articles in Baidu academic
[Yin G.]'s Articles
[Chio U.-F.]'s Articles
[Wei H.-G.]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Yin G.]'s Articles
[Chio U.-F.]'s Articles
[Wei H.-G.]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.