UM
Status已發表Published
An Ultrasensitive Fluorescent Breath Ammonia Sensor for Noninvasive Diagnosis of Chronic Kidney Disease and Helicobacter pylori infection
Song, G.; Jiang, D.; Wu, J.; Sun, X.; Deng, M.; Wang, L.; Hao, C.; Shi, J.; Liu, H.; Tian, Y.; Chen, M.
2022-07-15
Source PublicationChemical Engineering Journal
ISSN1385-8947
Pages135979-135979
AbstractBreath ammonia detection has been a significant non-invasive approach for disease diagnosis. However, the reported methods for breath ammonia detection suffer from high cost, time-consuming, complex operation, or low selectivity. Fluorescence analysis as an alternative method has not been introduced in the detection of breath ammonia due to its insufficient sensitivity. In this work, a rational designed strategy is proposed to improve the sensitivity of fluorescence sensors by increasing the amount of recognition site and enhancing the brightness of the solid-state fluorescence in sensor molecule. Briefly, three curcumin (CUR) derivatives BFCUR, MBFCUR and MBFCURM with D-π-A-π-D conjugated system were synthesized. Compared with the other two control molecules MBFCUR and MBFCURM, whose phenol groups at one or both ends of BFCUR were protected by methyl group, BFCUR has two response sites, thus, two intramolecular charge transfer (ICT) interactions occurred after exposure to ammonia, suggesting the improved sensitivity. Moreover, the large steric hindrance of boron trifluoride in BFCUR can prevent the π-π stacking of molecules and endow BFCUR with bright solid-state fluorescence. BFCUR was subsequently loaded into electrospun nanofibers (ENFs) with high specific surface area, which further improved the detection sensitivity. The obtained BFCUR-loaded ENFs sensor (denoted as BFCUR-ENF) exhibited ultra-low LOD of 22 ppb for ammonia. BFCUR-ENF is successfully applied to breath ammonia detection in healthy volunteers, patients with chronic kidney disease (CKD) and Helicobacter pylori (H. pylori) infection, demonstrating its great application potentials. Taken together, the first fluorescent sensor for breath ammonia detection was successfully constructed for noninvasive diagnosis of CKD and H. pylori.
Keywordbreath ammonia non-invasive diagnosis chronic kidney disease Helicobacter pylori electrospun nanofibers fluorescence sensor
URLView the original
Language英語English
The Source to ArticlePB_Publication
PUB ID63100
Document TypeJournal article
CollectionUniversity of Macau
Corresponding AuthorTian, Y.; Chen, M.
Recommended Citation
GB/T 7714
Song, G.,Jiang, D.,Wu, J.,et al. An Ultrasensitive Fluorescent Breath Ammonia Sensor for Noninvasive Diagnosis of Chronic Kidney Disease and Helicobacter pylori infection[J]. Chemical Engineering Journal, 2022, 135979-135979.
APA Song, G.., Jiang, D.., Wu, J.., Sun, X.., Deng, M.., Wang, L.., Hao, C.., Shi, J.., Liu, H.., Tian, Y.., & Chen, M. (2022). An Ultrasensitive Fluorescent Breath Ammonia Sensor for Noninvasive Diagnosis of Chronic Kidney Disease and Helicobacter pylori infection. Chemical Engineering Journal, 135979-135979.
MLA Song, G.,et al."An Ultrasensitive Fluorescent Breath Ammonia Sensor for Noninvasive Diagnosis of Chronic Kidney Disease and Helicobacter pylori infection".Chemical Engineering Journal (2022):135979-135979.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Song, G.]'s Articles
[Jiang, D.]'s Articles
[Wu, J.]'s Articles
Baidu academic
Similar articles in Baidu academic
[Song, G.]'s Articles
[Jiang, D.]'s Articles
[Wu, J.]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Song, G.]'s Articles
[Jiang, D.]'s Articles
[Wu, J.]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.