Residential College | false |
Status | 即將出版Forthcoming |
Novel miniaturized fluorescence loop-mediated isothermal amplification detection system for rapid on-site virus detection | |
Wu, Yanqi1,2; Bai, Liping1; Ye, Chengfu2; Yuhong Guan,2; Kunming Yan,2; Chen, Hui3; Jiang, Zhihong1 | |
2022-08-24 | |
Source Publication | Frontiers in Bioengineering and Biotechnology |
Volume | 10 |
Abstract | New pathogen outbreaks have progressed rapidly and are highly infectious in recent years, increasing the urgency of rapid and accurate detection of pathogenic microorganisms. Based on the point-of-care testing (POCT) requirements, in this study, a real-time fluorescent loop-mediated isothermal amplification (LAMP) detection system was developed and applied to pathogen detection. The system is compact and portable, with good uniformity and reproducibility, and it can detect pathogens rapidly and effectively. For norovirus detection, the linear range was 10–10 copies/μL. The system can achieve the theoretical sensitivity of LAMP detection, conclusions could be obtained within 35 min, and quantitative detection was possible. The test results of 45 clinical samples were consistent with quantitative PCR (qPCR) and clinical results, and the accuracy could reach 100%. This system has the characteristics of portability, speed, and POCT accuracy, and the cost is much lower than that of commercial qPCR. Therefore, it is suitable for remote areas or places with relatively poor conditions and environments requiring on-site conditions. It can also be widely used to detect various epidemics and unexpected diseases. |
Keyword | Aerosol Pollution Fluorescence Detection Lamp Norovirus Poct |
DOI | 10.3389/fbioe.2022.964244 |
URL | View the original |
Language | 英語English |
WOS Research Area | Biotechnology & Applied Microbiology ; Science & Technology - Other Topics |
WOS Subject | Biotechnology & Applied Microbiology |
WOS ID | WOS:000874163100001 |
Scopus ID | 2-s2.0-85138031581 |
Fulltext Access | |
Citation statistics | |
Document Type | Journal article |
Collection | University of Macau |
Affiliation | 1.State Key Laboratory of Quality Research in Chinese Medicine, Macau University of Science and Technology, Taipa, China 2.Shenzhen LemnisCare Medical Technology Co., Ltd, Shenzhen, China 3.Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou, China |
First Author Affilication | University of Macau |
Recommended Citation GB/T 7714 | Wu, Yanqi,Bai, Liping,Ye, Chengfu,et al. Novel miniaturized fluorescence loop-mediated isothermal amplification detection system for rapid on-site virus detection[J]. Frontiers in Bioengineering and Biotechnology, 2022, 10. |
APA | Wu, Yanqi., Bai, Liping., Ye, Chengfu., Yuhong Guan,., Kunming Yan,., Chen, Hui., & Jiang, Zhihong (2022). Novel miniaturized fluorescence loop-mediated isothermal amplification detection system for rapid on-site virus detection. Frontiers in Bioengineering and Biotechnology, 10. |
MLA | Wu, Yanqi,et al."Novel miniaturized fluorescence loop-mediated isothermal amplification detection system for rapid on-site virus detection".Frontiers in Bioengineering and Biotechnology 10(2022). |
Files in This Item: | There are no files associated with this item. |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment