UM  > INSTITUTE OF MICROELECTRONICS
Residential Collegefalse
Status已發表Published
17.2 A Miniature Multi-Nuclei NMR/MRI Platform with a High-Voltage SOI ASIC Achieving a 134.4dB Image SNR with a 173×250×103μm3Resolution
Fan, Shuhao1; Zhou, Qi1; Lei, Ka Meng1; Martins, Rui P.1,2; Mak, Pui In1
2024
Conference NameIEEE International Solid-State Circuits Conference
Source PublicationDigest of Technical Papers - IEEE International Solid-State Circuits Conference
Pages316-318
Conference Date2024-02
Conference PlaceSan Francisco, USA
PublisherInstitute of Electrical and Electronics Engineers Inc.
Abstract

Magnetic resonance imaging (MRI), based on Nuclear Magnetic Resonance (NMR), is an indispensable tool for contemporary medicine. Moreover, the advent of multi-nuclei MRI imaging, such as 1H/19F imaging using perfluorocarbon (PFC) nanoparticles, can detail anatomical and molecular information in a single session. It has revolutionized the field of molecular diagnostics and therapy monitoring by offering unprecedented insights into the physiological and pathological processes. While 1H MRI can reveal the object's anatomy, the ubiquitous presence of 1H in biological materials hinders effectiveness in tracking specific substances within the body (e.g., targeted drug delivery). Contrarily, as natural 19F is rare inside the body, it can serve as a marker for tracing substances with high specificity, thereby providing an accurate measure of the disease's extent or treatment efficacy.

DOI10.1109/ISSCC49657.2024.10454322
URLView the original
Language英語English
Scopus ID2-s2.0-85188077096
Fulltext Access
Citation statistics
Document TypeConference paper
CollectionINSTITUTE OF MICROELECTRONICS
DEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING
Affiliation1.University of Macau, Macao
2.Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal
First Author AffilicationUniversity of Macau
Recommended Citation
GB/T 7714
Fan, Shuhao,Zhou, Qi,Lei, Ka Meng,et al. 17.2 A Miniature Multi-Nuclei NMR/MRI Platform with a High-Voltage SOI ASIC Achieving a 134.4dB Image SNR with a 173×250×103μm3Resolution[C]:Institute of Electrical and Electronics Engineers Inc., 2024, 316-318.
APA Fan, Shuhao., Zhou, Qi., Lei, Ka Meng., Martins, Rui P.., & Mak, Pui In (2024). 17.2 A Miniature Multi-Nuclei NMR/MRI Platform with a High-Voltage SOI ASIC Achieving a 134.4dB Image SNR with a 173×250×103μm3Resolution. Digest of Technical Papers - IEEE International Solid-State Circuits Conference, 316-318.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Fan, Shuhao]'s Articles
[Zhou, Qi]'s Articles
[Lei, Ka Meng]'s Articles
Baidu academic
Similar articles in Baidu academic
[Fan, Shuhao]'s Articles
[Zhou, Qi]'s Articles
[Lei, Ka Meng]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Fan, Shuhao]'s Articles
[Zhou, Qi]'s Articles
[Lei, Ka Meng]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.