Residential College | false |
Status | 已發表Published |
17.2 A Miniature Multi-Nuclei NMR/MRI Platform with a High-Voltage SOI ASIC Achieving a 134.4dB Image SNR with a 173×250×103μm3Resolution | |
Fan, Shuhao1; Zhou, Qi1; Lei, Ka Meng1; Martins, Rui P.1,2; Mak, Pui In1 | |
2024 | |
Conference Name | IEEE International Solid-State Circuits Conference |
Source Publication | Digest of Technical Papers - IEEE International Solid-State Circuits Conference |
Pages | 316-318 |
Conference Date | 2024-02 |
Conference Place | San Francisco, USA |
Publisher | Institute of Electrical and Electronics Engineers Inc. |
Abstract | Magnetic resonance imaging (MRI), based on Nuclear Magnetic Resonance (NMR), is an indispensable tool for contemporary medicine. Moreover, the advent of multi-nuclei MRI imaging, such as 1H/19F imaging using perfluorocarbon (PFC) nanoparticles, can detail anatomical and molecular information in a single session. It has revolutionized the field of molecular diagnostics and therapy monitoring by offering unprecedented insights into the physiological and pathological processes. While 1H MRI can reveal the object's anatomy, the ubiquitous presence of 1H in biological materials hinders effectiveness in tracking specific substances within the body (e.g., targeted drug delivery). Contrarily, as natural 19F is rare inside the body, it can serve as a marker for tracing substances with high specificity, thereby providing an accurate measure of the disease's extent or treatment efficacy. |
DOI | 10.1109/ISSCC49657.2024.10454322 |
URL | View the original |
Language | 英語English |
Scopus ID | 2-s2.0-85188077096 |
Fulltext Access | |
Citation statistics | |
Document Type | Conference paper |
Collection | INSTITUTE OF MICROELECTRONICS DEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING |
Affiliation | 1.University of Macau, Macao 2.Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal |
First Author Affilication | University of Macau |
Recommended Citation GB/T 7714 | Fan, Shuhao,Zhou, Qi,Lei, Ka Meng,et al. 17.2 A Miniature Multi-Nuclei NMR/MRI Platform with a High-Voltage SOI ASIC Achieving a 134.4dB Image SNR with a 173×250×103μm3Resolution[C]:Institute of Electrical and Electronics Engineers Inc., 2024, 316-318. |
APA | Fan, Shuhao., Zhou, Qi., Lei, Ka Meng., Martins, Rui P.., & Mak, Pui In (2024). 17.2 A Miniature Multi-Nuclei NMR/MRI Platform with a High-Voltage SOI ASIC Achieving a 134.4dB Image SNR with a 173×250×103μm3Resolution. Digest of Technical Papers - IEEE International Solid-State Circuits Conference, 316-318. |
Files in This Item: | There are no files associated with this item. |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment