Residential College | false |
Status | 已發表Published |
Accuracy-enhanced variance-based time-skew calibration using SAR as window detector | |
Liu J.1; Chan C.-H.1; Sin S.-W.1; Seng-Pan U.1; Martins R.P.1 | |
2019-02-01 | |
Source Publication | IEEE Transactions on Very Large Scale Integration (VLSI) Systems |
ISSN | 1063-8210 |
Volume | 27Issue:2Pages:481-485 |
Abstract | This brief presents a time-interleaved (TI) successive-approximation-register (SAR) analog-to-digital converter (ADC) with an improved variance-based time-skew estimation technique, where we introduce a window detector (WD) based on a SAR ADC. It brings low hardware overhead and 10 times faster convergence speed when compared to the prior variance-based time-skew calibration. Postlayout simulation results of a 10-bit, 2-GS/s TI-ADC in 28-nm CMOS process verify the effectiveness of the proposed calibration. The results indicate that the signal noise and distortion ratio/spurious free dynamic range of the ADC improved from 41.9/48.6 to 53.2/63.3 dB after calibration. The total area and power are 0.105 mm and 14.9 mW, respectively, where the WD occupies 0.0015 mm and 0.55 mW. |
Keyword | Bandwidth Mismatches Split-digital To Analog Converter (Dac) Successive-approximation-register (Sar) Analog-to-digital Converter (Adc) Time-interleaved (Ti) Variance Based Window Detector (Wd) |
DOI | 10.1109/TVLSI.2018.2874772 |
URL | View the original |
Indexed By | SCIE |
Language | 英語English |
WOS Research Area | Computer Science ; Engineering |
WOS Subject | Computer Science, Hardware & Architecture ; Engineering, Electrical & Electronic |
WOS ID | WOS:000458069300019 |
Scopus ID | 2-s2.0-85055721763 |
Fulltext Access | |
Citation statistics | |
Document Type | Journal article |
Collection | INSTITUTE OF MICROELECTRONICS DEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING |
Corresponding Author | Chan C.-H. |
Affiliation | 1.Universidade de Macau 2.Synopsys Macau Ltd. 3.Instituto Superior Técnico |
First Author Affilication | University of Macau |
Corresponding Author Affilication | University of Macau |
Recommended Citation GB/T 7714 | Liu J.,Chan C.-H.,Sin S.-W.,et al. Accuracy-enhanced variance-based time-skew calibration using SAR as window detector[J]. IEEE Transactions on Very Large Scale Integration (VLSI) Systems, 2019, 27(2), 481-485. |
APA | Liu J.., Chan C.-H.., Sin S.-W.., Seng-Pan U.., & Martins R.P. (2019). Accuracy-enhanced variance-based time-skew calibration using SAR as window detector. IEEE Transactions on Very Large Scale Integration (VLSI) Systems, 27(2), 481-485. |
MLA | Liu J.,et al."Accuracy-enhanced variance-based time-skew calibration using SAR as window detector".IEEE Transactions on Very Large Scale Integration (VLSI) Systems 27.2(2019):481-485. |
Files in This Item: | There are no files associated with this item. |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment