Residential Collegefalse
Status已發表Published
Experimental investigation of the local web buckling strength of coped steel i-beam with and without stiffeners
Lam A.C.C.2; Yam M.C.H.1; Fu C.K.M.2
2006-12-01
Conference NameThe Tenth East Asia-Pacific Conference on Structural Engineering & Construction
Source PublicationReal Structures: Bridges and Tall Buildings - Proceedings of the 10th East Asia-Pacific Conference on Structural Engineering and Construction, EASEC 2010
Volume4
Pages559-564
Conference DateAugust, 3-5
Conference PlaceBangkok, Thailand
Abstract

In steel construction, when beams have to be connected at the same elevation, beam flanges must often be coped to provide enough clearance for the supports. When a beam is coped, local web buckling of the cope region may occur especially when the cope length is long. The elastic local web buckling capacity of coped steel I-beam had been investigated by the authors and a set of design equations was proposed. In order to improve the local web capacity of the cope region, stiffeners should be provided. However, there are only very limited research works about the local web capacity of the cope region with stiffeners. Therefore, an experimental investigation of the local web buckling strength of coped steel I-beam with and without stiffeners was carried out and the results were presented in this paper. Test results showed that to improve the local web capacity at the cope, both horizontal and vertical stiffeners should be provided instead of providing horizontal stiffeners only. In this study, for specimens with both horizontal and vertical stiffeners at the cope, the web capacity at the cope region was increased significantly and the applied load at failure of those specimens was close to the applied load corresponding to achieving the plastic moment capacity of the section. © 2006 by School of Engineering and Technology, Asian Institute of Technology.

KeywordCope Beam Local Web Buckling Steel Structures Design Stiffeners
URLView the original
Language英語English
Fulltext Access
Document TypeConference paper
CollectionDEPARTMENT OF CIVIL AND ENVIRONMENTAL ENGINEERING
Affiliation1.Hong Kong Polytechnic University
2.Universidade de Macau
First Author AffilicationUniversity of Macau
Recommended Citation
GB/T 7714
Lam A.C.C.,Yam M.C.H.,Fu C.K.M.. Experimental investigation of the local web buckling strength of coped steel i-beam with and without stiffeners[C], 2006, 559-564.
APA Lam A.C.C.., Yam M.C.H.., & Fu C.K.M. (2006). Experimental investigation of the local web buckling strength of coped steel i-beam with and without stiffeners. Real Structures: Bridges and Tall Buildings - Proceedings of the 10th East Asia-Pacific Conference on Structural Engineering and Construction, EASEC 2010, 4, 559-564.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Lam A.C.C.]'s Articles
[Yam M.C.H.]'s Articles
[Fu C.K.M.]'s Articles
Baidu academic
Similar articles in Baidu academic
[Lam A.C.C.]'s Articles
[Yam M.C.H.]'s Articles
[Fu C.K.M.]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Lam A.C.C.]'s Articles
[Yam M.C.H.]'s Articles
[Fu C.K.M.]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.