Abstract

The silver/silver chloride (Ag/AgCl) electrode is a widely-used electrode type for signal stimulation and detection in many groups during their Intra-body communication (IBC) investigations. Silver ions may reside in the human body during the IBC process. This may cause argyria and argyrosis due to the accumulation over time. In this article, IBC pseudo-experiments of signal stimulation and detection by using Ag/AgCl electrodes are designed and conducted to measure the amount of silver ion residue. For the sake of safety and simplicity, physiological saline is used instead of the human in the experiments. The stimulation and detection experiments in galvanic coupling method as well as the capacitive coupling method show that there exists silver ion residual. Although the amount of the silver ion residue is remained within the safety standard in each experiment, it may be not safe by using the Ag/AgCl electrodes frequently.

KeywordDetection Intrabody Communication (Ibc) Silver/silver Chloride (Ag/agcl) Electrode Stimulation
DOI10.1109/ICCE-China.2016.7849762
URLView the original
Indexed BySCIE
Language英語English
WOS Research AreaEngineering
WOS SubjectEngineering, Electrical & Electronic
WOS IDWOS:000400497700037
Scopus ID2-s2.0-85015213282
Fulltext Access
Citation statistics
Document TypeConference paper
CollectionDEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING
Affiliation1.Universidade de Macau
2.Key Lab of Medical Instrumentation and Pharmaceutical Technology of Fujian Province
First Author AffilicationUniversity of Macau
Recommended Citation
GB/T 7714
Tang X.,Chen X.M.,Mak P.U.,et al. Investigation of residual Ag amount into human body using Ag/AgCl electrodes during IBC[C], 2017.
APA Tang X.., Chen X.M.., Mak P.U.., Gao Y.., & Vai M.I. (2017). Investigation of residual Ag amount into human body using Ag/AgCl electrodes during IBC. 2016 IEEE International Conference on Consumer Electronics-China, ICCE-China 2016.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Tang X.]'s Articles
[Chen X.M.]'s Articles
[Mak P.U.]'s Articles
Baidu academic
Similar articles in Baidu academic
[Tang X.]'s Articles
[Chen X.M.]'s Articles
[Mak P.U.]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Tang X.]'s Articles
[Chen X.M.]'s Articles
[Mak P.U.]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.