Residential College | false |
Status | 已發表Published |
Direct Measurement of Elbow Joint Angle Using Galvanic Couple System | |
Chen, Xi Mei1; Barma, Shovan2; Pun, Sio Hang1; Vai, Mang I.1; Mak, Peng Un1 | |
2017-04 | |
Source Publication | IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT |
ISSN | 0018-9456 |
Volume | 66Issue:4Pages:757-766 |
Abstract | This paper proposes a simple approach to measure the elbow joint angle (EJA) using galvanic coupling system (GCS), directly; whereas, the traditional methods involved in either complex machine-learning task or arm movement models in which the consideration of model parameters are not accurate very often. First, a correlation between the EJA and GCS data has been established by defining a polynomial function based on a simple six-impedance model of human upper arm, where the EJA (theta) has been achieved by moving the forearm along the sagittal and transverse planes with different loads (empty hand, 1 and 2 kg). The coefficients of the polynomial are estimated based on the polynomial fit technique in which the actual angles (reference frame) are calculated by using motion data. In total, eleven subjects (seven males and four females) with the age of 30 +/- 6 years have been considered during the experiment. However, the GCS data of eight subjects are used to derive the correlation, exclusively. Furthermore, the influence of muscle fatigue and different loads on the derived correlation has been studied. Next, based on the derived correlation, the EJA has been measured in two parts-inside and outside tests by considering six subjects. The results show that the proposed idea can measure the EJA very effectively with error up to +/- 0.11 rad (6 degrees). Moreover, in a performance comparison, the proposed approach shows its compatibility by indicating low complexity, higher accuracy, and easy to measure. |
Keyword | Forearm Movement Galvanic Coupling System (Gcs) Measurement Of Elbow Joint Angle (Eja) Upper Arm Muscle |
DOI | 10.1109/TIM.2017.2654138 |
URL | View the original |
Indexed By | SCIE |
Language | 英語English |
WOS Research Area | Engineering ; Instruments & Instrumentation |
WOS Subject | Engineering, Electrical & Electronic ; Instruments & Instrumentation |
WOS ID | WOS:000396397900018 |
Publisher | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC |
The Source to Article | WOS |
Scopus ID | 2-s2.0-85012113357 |
Fulltext Access | |
Citation statistics | |
Document Type | Journal article |
Collection | INSTITUTE OF MICROELECTRONICS DEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING |
Affiliation | 1.University of Macau 2.Indian Inst Informat Technol |
First Author Affilication | University of Macau |
Recommended Citation GB/T 7714 | Chen, Xi Mei,Barma, Shovan,Pun, Sio Hang,et al. Direct Measurement of Elbow Joint Angle Using Galvanic Couple System[J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2017, 66(4), 757-766. |
APA | Chen, Xi Mei., Barma, Shovan., Pun, Sio Hang., Vai, Mang I.., & Mak, Peng Un (2017). Direct Measurement of Elbow Joint Angle Using Galvanic Couple System. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 66(4), 757-766. |
MLA | Chen, Xi Mei,et al."Direct Measurement of Elbow Joint Angle Using Galvanic Couple System".IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT 66.4(2017):757-766. |
Files in This Item: | There are no files associated with this item. |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment