A High DR High-Input-Impedance Programmable-Gain ECG Acquisition Interface with Non-inverting Continuous Time Sigma-Delta Modulator | |
Junhao Liang1; Sai-Weng Sin1; U. Seng-Pan2; Franco Maloberti2; R.P. Martins1,3; Hanjun Jiang4 | |
2019-11-01 | |
Conference Name | 15th IEEE Asian Solid-State Circuits Conference, A-SSCC 2019 |
Source Publication | Proceedings - 2019 IEEE Asian Solid-State Circuits Conference, A-SSCC 2019 |
Pages | 309-312 |
Conference Date | 04-06 November 2019 |
Conference Place | Macao, China |
Country | China |
Publisher | IEEE |
Abstract | This paper presents a power-efficient, high dynamic range, high input impedance data acquisition circuit for an implantable electrocardiogram (ECG) detector in 65 nm CMOS, occupying an active area of 0.225 mm. To enhance the dynamic range, we utilize a 3-order continuous-time sigma-delta modulator with a programmable input gain coefficient and an embedded antialiasing filter. The implementation of the non-inverting integrator allows a high input impedance for the ECG application. The measurement results show that it obtains 84.2dB SNDR in a 150Hz bandwidth with a 1V power supply, consuming 5.4μW at a nominal gain of 0dB. The maximum dynamic range is 99.3dB with the programmable gain activated from 0 to 18dB. |
Keyword | Ct Sigma Delta Ad Converter Ecg High Impedance Non-invertering Integrator Programmable Integrator |
DOI | 10.1109/A-SSCC47793.2019.9056891 |
URL | View the original |
Indexed By | CPCI-S ; EI |
Language | 英語English |
WOS Research Area | Engineering |
WOS Subject | Engineering, Electrical & Electronic |
WOS ID | WOS:000569524500088 |
The Source to Article | https://ieeexplore.ieee.org/document/9056891/keywords#keywords |
Scopus ID | 2-s2.0-85083634822 |
Fulltext Access | |
Citation statistics | |
Document Type | Conference paper |
Collection | INSTITUTE OF MICROELECTRONICS Faculty of Science and Technology DEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING |
Corresponding Author | Sai-Weng Sin |
Affiliation | 1.State-Key Laboratory of Analog and Mixed-Signal VLSI,IME/ECE/FST,University of Macau,Macao 2.University of Pavia, Pavia, Italy 3.Instituto Superior Técnico, Universidade de Lisboa, Portugal Hanjun Jiang The Institute of Microelectronics, Tsinghua University, Beijing, China Figures References Citations Keywords Metrics Back to Results More Like This Digitization of electrocardio 4.The Institute of Microelectronics, Tsinghua University, Beijing, China |
First Author Affilication | Faculty of Science and Technology |
Corresponding Author Affilication | Faculty of Science and Technology |
Recommended Citation GB/T 7714 | Junhao Liang,Sai-Weng Sin,U. Seng-Pan,et al. A High DR High-Input-Impedance Programmable-Gain ECG Acquisition Interface with Non-inverting Continuous Time Sigma-Delta Modulator[C]:IEEE, 2019, 309-312. |
APA | Junhao Liang., Sai-Weng Sin., U. Seng-Pan., Franco Maloberti., R.P. Martins., & Hanjun Jiang (2019). A High DR High-Input-Impedance Programmable-Gain ECG Acquisition Interface with Non-inverting Continuous Time Sigma-Delta Modulator. Proceedings - 2019 IEEE Asian Solid-State Circuits Conference, A-SSCC 2019, 309-312. |
Files in This Item: | There are no files associated with this item. |