Residential Collegefalse
Status已發表Published
On an automatic delineator for arterial blood pressure waveforms
Bing Nan Li1,2; Ming Chui Dong1,3; Mang I. Vai1
2010-01
Source PublicationBiomedical signal processing and control
ISSN1746-8094
Volume5Issue:1Pages:76-81
Abstract

Arterial blood pressure waveforms contain rich pathophysiological information; hence receive much attention in cardiovascular health monitoring. To assist computerized analysis, an automatic delineator was proposed for the fiducial points of arterial blood pressure waveforms, namely their onsets, systolic peaks and dicrotic notches. The presented delineator characterizes arterial blood pressure waveforms in a beat-by-beat manner. It firstly seeks the pairs of inflection and zero-crossing points, and then utilizes combinatorial amplitude and interval criteria to select the onset and systolic peak. Once a new beat is settled, the delineator seeks the derivative backward to locate the dicrotic notch in the preceding beat. In a nutshell, the delineator is based on the combinatorial analysis of arterial blood pressure waveforms and their derivatives. Three open databases, with an additional subset database, were utilized for delineator validation and performance evaluation. In terms of beat detection, the delineator achieved an average error rate 1.14%, sensitivity 99.43% and positive predictivity 99.45%. As to dicrotic notch detection, it performed well with an error rate 6.83%, sensitivity 96.53% and positive predictivity 96.64%. 

KeywordArterial Blood Pressure Waveforms Cardiovascular System Dicrotic Notch Detection Pulse Contour Analysis
DOI10.1016/j.bspc.2009.06.002
URLView the original
Indexed BySCIE
Language英語English
WOS Research AreaEngineering ; Medical Laboratory Technology
WOS SubjectEngineering, Biomedical ; Medical Laboratory Technology
WOS IDWOS:000274689200011
PublisherELSEVIER SCI LTD, THE BOULEVARD, LANGFORD LANE, KIDLINGTON, OXFORD OX5 1GB, OXON, ENGLAND
The Source to ArticleScopus
Scopus ID2-s2.0-75049084629
Fulltext Access
Citation statistics
Document TypeJournal article
CollectionDEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING
Corresponding AuthorMing Chui Dong; Mang I. Vai
Affiliation1.Department of Electrical and Electronics Engineering, University of Macau, Taipa 1356, Macau
2.NUS Graduate School for Integrative Science and Engineering, National University of Singapore, Kent Ridge 117456, Singapore
3.Institute of Systems and Computer Engineering of Macau, Taipa 1356, Macau
First Author AffilicationUniversity of Macau
Corresponding Author AffilicationUniversity of Macau
Recommended Citation
GB/T 7714
Bing Nan Li,Ming Chui Dong,Mang I. Vai. On an automatic delineator for arterial blood pressure waveforms[J]. Biomedical signal processing and control, 2010, 5(1), 76-81.
APA Bing Nan Li., Ming Chui Dong., & Mang I. Vai (2010). On an automatic delineator for arterial blood pressure waveforms. Biomedical signal processing and control, 5(1), 76-81.
MLA Bing Nan Li,et al."On an automatic delineator for arterial blood pressure waveforms".Biomedical signal processing and control 5.1(2010):76-81.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Bing Nan Li]'s Articles
[Ming Chui Dong]'s Articles
[Mang I. Vai]'s Articles
Baidu academic
Similar articles in Baidu academic
[Bing Nan Li]'s Articles
[Ming Chui Dong]'s Articles
[Mang I. Vai]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Bing Nan Li]'s Articles
[Ming Chui Dong]'s Articles
[Mang I. Vai]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.