Simulation of a High-Sensitivity Adjustable-FOV PET Scanner
Ozsahin,Ilker1,2; Musa,Musa Sani1; Mok,Greta S.P.2
2018-11-01
PublisherIEEE
Publication PlaceUSA
Abstract

The aim of this study is to evaluate a new Positron Emission Tomography (PET) geometry to improve the overall system sensitivity and design a patient/disease specific adjustable field of view (FOV). We proposed a PET system design which was simulated using Geant4 based Architecture for Medicine Oriented Simulations (GAMOS) software. We call this design "sandwich-PET" because the system with the size of 66.2 cm and 198.6 cm on the transaxial and axial direction, respectively, resembles a sandwich when the patient is between the detector heads. The system is intended for whole-body studies, while it can also be used for brain and cardiac studies. The system's transaxial FOV can be adjusted by moving the detector heads in the same or opposite direction, depending on the patient type. It employs lutetium yttrium oxyorthosilicate (LYSO) crystals with 2.76×2.76×18.1 mm pixel sizes. The performance evaluation test was conducted using two simulated line sources placed at the center on the axial and transaxial FOV. The coincidence events were detected with an energy window of 350-650 keV, and a coincidence time window of 20 ns. The result showed that the system's sensitivity increases exponentially when varying the transaxial FOV from 70 cm (regular openings for conventional PET scanners for all type of patients: slim, overweight, or obese) down to 20 cm (for slim or pediatric patients). This study shows that the system is capable of achieving much higher sensitivity comparing to the conventional whole-body scanners.

KeywordAdjustable-fov Gamos High-sensitivity Pet Simulation
DOI10.1109/NSSMIC.2018.8824440
URLView the original
Language英語English
Fulltext Access
Citation statistics
Document TypeConference proceedings
CollectionDEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING
Affiliation1.Department of Biomedical Engineering,Faculty of Engineering,Near East University Nicosia,Mersin 10 TRNC,99138,Turkey
2.Biomedical Imaging Laboratory,Department of Electrical and Computer Engineering,Faculty of Science and Technology,University of Macau,Macao
First Author AffilicationFaculty of Science and Technology
Recommended Citation
GB/T 7714
Ozsahin,Ilker,Musa,Musa Sani,Mok,Greta S.P.. Simulation of a High-Sensitivity Adjustable-FOV PET Scanner[C]. USA:IEEE, 2018.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Ozsahin,Ilker]'s Articles
[Musa,Musa Sani]'s Articles
[Mok,Greta S.P.]'s Articles
Baidu academic
Similar articles in Baidu academic
[Ozsahin,Ilker]'s Articles
[Musa,Musa Sani]'s Articles
[Mok,Greta S.P.]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Ozsahin,Ilker]'s Articles
[Musa,Musa Sani]'s Articles
[Mok,Greta S.P.]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.