Development of a calibration strip forimmunochromatographic assay detection systems
Gao,Yue Ming1,2; Wei,Jian Chong1,2,3; Mak,Peng Un2,4; Vai,Mang I.2,3,4; Du,Min1,2; Pun,Sio Hang3
2016
Source PublicationSensors (Switzerland)
ISSN1424-8220
Volume16Issue:7
Abstract

With many benefits and applications, immunochromatographic (ICG) assay detection systems have been reported on a great deal. However, the existing research mainly focuses on increasing the dynamic detection range or application fields. Calibration of the detection system, which has a great influence on the detection accuracy, has not been addressed properly. In this context, this work develops a calibration strip for ICG assay photoelectric detection systems. An image of the test strip is captured by an image acquisition device, followed by performing a fuzzy c-means (FCM) clustering algorithm and maximin-distance algorithm for image segmentation. Additionally, experiments are conducted to find the best characteristic quantity. By analyzing the linear coefficient, an average value of hue (H) at 14 min is chosen as the characteristic quantity and the empirical formula between H and optical density (OD) value is established. Therefore, H, saturation (S), and value (V) are calculated by a number of selected OD values. Then, H, S, and V values are transferred to the RGB color space and a high-resolution printer is used to print the strip images on cellulose nitrate membranes. Finally, verification of the printed calibration strips is conducted by analyzing the linear correlation between OD and the spectral reflectance, which shows a good linear correlation (R = 98.78%).

KeywordCalibration Strip Fuzzy C-means (Fcm) Algorithm Immunochromatographic (Icg) Assay Maximin-distance Algorithm
DOI10.3390/s16071007
URLView the original
Language英語English
WOS IDWOS:000380967000065
Scopus ID2-s2.0-84976574258
Fulltext Access
Citation statistics
Document TypeJournal article
CollectionTHE STATE KEY LABORATORY OF ANALOG AND MIXED-SIGNAL VLSI (UNIVERSITY OF MACAU)
INSTITUTE OF MICROELECTRONICS
DEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING
Affiliation1.College of Physics and Information Engineering,Fuzhou University,Fuzhou,350116,China
2.Key Lab of Medical Instrumentation and Pharmaceutical Technology of Fujian Province,Fuzhou,350116,China
3.State Key Laboratory of Analog and Mixed Signal VLSI,University of Macau,Macau,999078,Macao
4.Department of Electrical and Computer Engineering,Faculty of Science and Technology,University of Macau,Macau,999078,Macao
Recommended Citation
GB/T 7714
Gao,Yue Ming,Wei,Jian Chong,Mak,Peng Un,et al. Development of a calibration strip forimmunochromatographic assay detection systems[J]. Sensors (Switzerland), 2016, 16(7).
APA Gao,Yue Ming., Wei,Jian Chong., Mak,Peng Un., Vai,Mang I.., Du,Min., & Pun,Sio Hang (2016). Development of a calibration strip forimmunochromatographic assay detection systems. Sensors (Switzerland), 16(7).
MLA Gao,Yue Ming,et al."Development of a calibration strip forimmunochromatographic assay detection systems".Sensors (Switzerland) 16.7(2016).
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Gao,Yue Ming]'s Articles
[Wei,Jian Chong]'s Articles
[Mak,Peng Un]'s Articles
Baidu academic
Similar articles in Baidu academic
[Gao,Yue Ming]'s Articles
[Wei,Jian Chong]'s Articles
[Mak,Peng Un]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Gao,Yue Ming]'s Articles
[Wei,Jian Chong]'s Articles
[Mak,Peng Un]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.