Residential College | false |
Status | 已發表Published |
High-throughput fluorescence polarization method for identifying ligands of LOX-1 | |
Zhang T.-T.; Huang Z.-T.; Dai Y.; Chen X.-P.![]() | |
2006-04-01 | |
Source Publication | Acta Pharmacologica Sinica
![]() |
ISSN | 16714083 17457254 |
Volume | 27Issue:4Pages:447-452 |
Abstract | Aim: To develop and optimize a competitive fluorescence polarization (FP) method, and use it as a high-throughput screening (HTS) assay for drug discovery. Methods: Human lectin-like oxidized low-density lipoprotein receptor-1 (hLOX-1) and oxidized low-density lipoprotein (oxLDL) were used to establish a high-throughput fluorescence polarization assay to screen ligands of human LOX-1. A 96-well plate assay was performed with a fast plate reader. Three fluorescein isothiocyanate-labeled hLOX-1 concentrations (100, 200, and 400 nmol/L) were selected to be titrated by oxLDL (from 0.05 nmol/L to 100 μmol/L) in order to obtain optimal reactive concentrations. The concentration of MeSO used (0%, 1%, 3%, 5%) and incubation time (15 min, 30 min, 1h, 2h) were optimized. The Z' factor was calculated to estimate the quality of FP-based HTS. Results: Concentrations of 200 nmol/L for human LOX-1 and 50 μmol/L for oxLDL were used in the actual assay. Concentrations of 0% to 5% MeSO and different reaction times did not affect the FP-based HTS. The Z' value was 0.66. By using this detection and screening system, 12 700 compounds were screened and 3 ligands with an IC50 of less than 4.5 μmol/L were found. Conclusion: The established competitive FP-based assay is sensitive, stable, highly reproducible and robust, and suitable for HTS for ligands of the hLOX-1 receptor. ©2006 CPS and SIMM. |
Keyword | Fluorescence Polarization Assay High-throughput Screening Ldl Receptors Oxidized Low Density Lipoprotein |
DOI | 10.1111/j.1745-7254.2006.00281.x |
URL | View the original |
Indexed By | SCIE |
Language | 英語English |
WOS Research Area | Chemistry ; Pharmacology & Pharmacy |
WOS Subject | Chemistry, Multidisciplinary ; Pharmacology & Pharmacy |
WOS ID | WOS:000236176900010 |
Scopus ID | 2-s2.0-33645213887 |
Fulltext Access | |
Citation statistics | |
Document Type | Journal article |
Collection | Institute of Chinese Medical Sciences |
Affiliation | Chinese Academy of Medical Sciences |
Recommended Citation GB/T 7714 | Zhang T.-T.,Huang Z.-T.,Dai Y.,et al. High-throughput fluorescence polarization method for identifying ligands of LOX-1[J]. Acta Pharmacologica Sinica, 2006, 27(4), 447-452. |
APA | Zhang T.-T.., Huang Z.-T.., Dai Y.., Chen X.-P.., Zhu P.., & Du G.-H. (2006). High-throughput fluorescence polarization method for identifying ligands of LOX-1. Acta Pharmacologica Sinica, 27(4), 447-452. |
MLA | Zhang T.-T.,et al."High-throughput fluorescence polarization method for identifying ligands of LOX-1".Acta Pharmacologica Sinica 27.4(2006):447-452. |
Files in This Item: | There are no files associated with this item. |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment