UM
Residential Collegefalse
Status已發表Published
Two-dimension fault line selection method based on transient signal features of fault phase
Zhang W.2; Yang J.2; Xiao X.2; Wang Y.2
2012
Conference NameInternational Conference on Energy, Environment and Sustainable Development (ICEESD 2011)
Source PublicationAdvanced Materials Research
Volume354-355
Pages1289-1292
Conference DateOCT 21-23, 2011
Conference PlaceShanghai Univ Elect Power, Shanghai, PEOPLES R CHINA
Abstract

When single-line-to-ground fault happen in neutral non-effectively earthed system, there is a big difference between the fault feeder and un-fault feeder in transient signal energy centralized frequency band and signal amplitude of fault phase. The transient signal energy in fault feeder's fault phase is bigger, and it centralizes in lower frequency band. But the transient signal in un-fault feeders' has the contrary features. And this feature is affected little by the fault initial angle. So the paper proposed a method that using the gravity frequency and transient signal energy to form a two-dimension line selection method that using the signal overall distribution characteristics. It can be applied in neutral unearthed and resonant system simultaneously. And the method is effectively to different fault initial angle and fault resistance. The method is proved correctly, effectively and adaptively by actual simulation in different fault cases. © (2012) Trans Tech Publications.

KeywordDistribution System Fault Line Selection Gravity Frequency Neutral Non-effectively Earthed System Transient Signal Energy Two-dimension Fault Line Selection Criteria
DOI10.4028/www.scientific.net/AMR.354-355.1289
URLView the original
Language英語English
WOS IDWOS:000309370300243
Scopus ID2-s2.0-80155129969
Fulltext Access
Citation statistics
Document TypeConference paper
CollectionUniversity of Macau
Affiliation1.Smart Grid Key Laboratory of Sichuan Province
2.Sichuan University
Recommended Citation
GB/T 7714
Zhang W.,Yang J.,Xiao X.,et al. Two-dimension fault line selection method based on transient signal features of fault phase[C], 2012, 1289-1292.
APA Zhang W.., Yang J.., Xiao X.., & Wang Y. (2012). Two-dimension fault line selection method based on transient signal features of fault phase. Advanced Materials Research, 354-355, 1289-1292.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Zhang W.]'s Articles
[Yang J.]'s Articles
[Xiao X.]'s Articles
Baidu academic
Similar articles in Baidu academic
[Zhang W.]'s Articles
[Yang J.]'s Articles
[Xiao X.]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Zhang W.]'s Articles
[Yang J.]'s Articles
[Xiao X.]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.