UM

Browse/Search Results:  1-10 of 11 Help

Selected(0)Clear Items/Page:    Sort:
A 0.32 × 0.12 mm2 Cryogenic BiCMOS 0.1–8.8 GHz Low Noise Amplifier Achieving 4 K Noise Temperature for SNWD Readout Journal article
Peng, Yatao, Benserhir, Jad, Castaneda, Mario, Fognini, Andreas, Bruschini, Claudio, Charbon, Edoardo. A 0.32 × 0.12 mm2 Cryogenic BiCMOS 0.1–8.8 GHz Low Noise Amplifier Achieving 4 K Noise Temperature for SNWD Readout[J]. IEEE Transactions on Microwave Theory and Techniques, 2024, 72(4), 2179-2192.
Authors:  Peng, Yatao;  Benserhir, Jad;  Castaneda, Mario;  Fognini, Andreas;  Bruschini, Claudio; et al.
Favorite | TC[WOS]:2 TC[Scopus]:2  IF:4.1/4.2 | Submit date:2024/05/02
Bicmos  Cryogenic Temperatures  Low-noise Amplifiers  Sige Heterojunction Bipolar Transistor (Hbt)  Superconducting Single-photon Detectors  Timing Jitter  
Nonlinear Infrared Photodetection Based on Strong Nondegenerate Two-Photon Absorption of Perovskite Single Crystal Journal article
Wang, Wei, Wei, Qi, Gong, Yiyang, Xing, Guichuan, Wu, Bo, Zhou, Guofu. Nonlinear Infrared Photodetection Based on Strong Nondegenerate Two-Photon Absorption of Perovskite Single Crystal[J]. Advanced Optical Materials, 2022, 10(16), 2200400.
Authors:  Wang, Wei;  Wei, Qi;  Gong, Yiyang;  Xing, Guichuan;  Wu, Bo; et al.
Favorite | TC[WOS]:4 TC[Scopus]:4  IF:8.0/9.0 | Submit date:2022/06/14
Infrared Photodetection  Nondegenerate Two-photon Absorption  Perovskite Single Crystals  
The clinical utilities of multi-pinhole single photon emission computed tomography Review article
2020
Authors:  Ozsahin,Ilker;  Chen,Ling;  Könik,Arda;  King,Michael A.;  Beekman,Freek J.; et al.
Favorite | TC[WOS]:17 TC[Scopus]:22  IF:2.9/3.2 | Submit date:2021/03/11
Brain  Cardiac  Collimator  Multi-pinhole  Single Photon Emission Computed Tomography (Spect)  
A 4μm Diameter SPAD Using Less-doped N-Well Guard Ring in Baseline 65nm CMOS Journal article
Lu, X., Law, M. K., Jiang, Y., Zhao, X., Mak, P. I., Martins, R. P.. A 4μm Diameter SPAD Using Less-doped N-Well Guard Ring in Baseline 65nm CMOS[J]. IEEE Transactions on Electron Devices, 2020, 2223-2225.
Authors:  Lu, X.;  Law, M. K.;  Jiang, Y.;  Zhao, X.;  Mak, P. I.; et al.
Favorite |   IF:2.9/2.9 | Submit date:2022/01/25
Baseline CMOS  Premature Lateral Break-Down  Single-Photon Avalanche Diode (SPAD)  Small Pitch  
A 4-μm diameter SPAD using less-doped N-Well guard ring in baseline 65-nm CMOS Journal article
Lu,Xin, Law,Man Kay, Jiang,Yang, Zhao,Xiaojin, Mak,Pui In, Martins,Rui P.. A 4-μm diameter SPAD using less-doped N-Well guard ring in baseline 65-nm CMOS[J]. IEEE TRANSACTIONS ON ELECTRON DEVICES, 2020, 67(5), 2223-2225.
Authors:  Lu,Xin;  Law,Man Kay;  Jiang,Yang;  Zhao,Xiaojin;  Mak,Pui In; et al.
Favorite | TC[WOS]:14 TC[Scopus]:16  IF:2.9/2.9 | Submit date:2021/03/04
Baseline Cmos  Premature Lateral Breakdown  Single-photon Avalanche Diode (Spad)  Small Pitch  
Comparison of Different Attenuation Correction Methods for Dual Gating Myocardial Perfusion SPECT/CT Journal article
Qi Zhang, Duo Zhang, Greta S. P. Mok. Comparison of Different Attenuation Correction Methods for Dual Gating Myocardial Perfusion SPECT/CT[J]. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2019, 3(5), 565-571.
Authors:  Qi Zhang;  Duo Zhang;  Greta S. P. Mok
Favorite | TC[WOS]:7 TC[Scopus]:8  IF:4.6/3.6 | Submit date:2020/06/12
Attenuation Correction (Ac)  Dual Gating  Myocardial Perfusion  Single Photon Emission Computed Tomography (Spect)/ct  
Upconversion single-microbelt photodetector via two-photon absorption simultaneous Journal article
Guanlin Lou, Yanyan Wu, Hai Zhu, Jinyu Li, Anqi Chen, Zhiyang Chen, Yunfeng Liang, Yuhao Ren, Xuchun Gui, Dingyong Zhong, Zhiren Qiu, Zikang Tang, Shi C Su. Upconversion single-microbelt photodetector via two-photon absorption simultaneous[J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2018, 51(19).
Authors:  Guanlin Lou;  Yanyan Wu;  Hai Zhu;  Jinyu Li;  Anqi Chen; et al.
Favorite | TC[WOS]:6 TC[Scopus]:3  IF:3.1/3.0 | Submit date:2018/10/30
Single-photon  Two-photon  Upconversion  Microbelt  Photodetector  
Evaluation of Stationary and Semi-stationary Acquisitions from Dual-head Multi-pinhole Collimator for Myocardial Perfusion SPECT Journal article
Yan P., Chen L., Tsui B.M.W., Mok G.S.P.. Evaluation of Stationary and Semi-stationary Acquisitions from Dual-head Multi-pinhole Collimator for Myocardial Perfusion SPECT[J]. Journal of Medical and Biological Engineering, 2016, 36(5), 675-685.
Authors:  Yan P.;  Chen L.;  Tsui B.M.W.;  Mok G.S.P.
Favorite | TC[WOS]:6 TC[Scopus]:8 | Submit date:2018/12/18
Multi-pinhole  Myocardial Perfusion  Single-photon Emission Computed Tomography (Spect)  Stationary Acquisition  
PET/SPECT molecular imaging in clinical neuroscience: recent advances in the investigation of CNS diseases Journal article
Feng-Mei Lu, Zhen Yuan. PET/SPECT molecular imaging in clinical neuroscience: recent advances in the investigation of CNS diseases[J]. Quantitative Imaging in Medicine and Surgery, 2015, 5(3), 433-447.
Authors:  Feng-Mei Lu;  Zhen Yuan
Favorite | TC[WOS]:131 TC[Scopus]:0  IF:2.9/3.2 | Submit date:2019/01/03
Molecular Imaging  Central Nervous System (Cns) Diseases  Positron Emission Tomography (Pet)  Single Photon Emission Computed Tomography (Spect)  
Evaluation of Stationary and Semi-stationary Acquisitions in a Dual-head Multi-pinhole Collimator for Myocardial Perfusion SPECT Conference proceedings
Journal of Medical and Biological Engineering, 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), Seattle, WA, USA, 2014
Authors:  Yan, PY;  Chen, L;  Tsui, BMW;  Mok, S. P.
Favorite |  | Submit date:2022/07/02
Single-photon Emission Computed Tomography (Spect)  Myocardial Perfusion  Multi-pinhole  Stationary Acquisition